CARRIER INVERTER AIR CONDITIONER ERROR CODES
Error Code |
Outdoor Light Flash times |
Description |
OUTDOOR FAULT |
||
F4 |
1 |
Outdoor EEPROM fault |
E1 |
2 |
Indoor to Outdoor communication fault |
P4 |
4 |
Compressor starting abnormal |
P4 |
5 |
Compressor out-of-step abnormal |
P0 |
6 |
IPM module fault |
P2 |
7 |
Compressor shell temperature overheat protection |
F3 |
8 |
Compressor discharge temperature overheat
protection |
F8 |
9 |
Compressor suction temperature sensor
fault |
F2 |
10 |
Outdoor condenser temperature sensor
fault |
F1 |
11 |
Outdoor ambient temperature sensor fault |
F5 |
12 |
Outdoor DC fan motor fault |
L3 |
33 |
Drive phase current overload fault |
L4 |
34 |
Phase current sampling fault |
PROTECTION |
||
F0 |
13 |
Outdoor AC current protection |
P5 |
14 |
Compressor phase current protection |
P1 |
15 |
Outdoor unit over-high/over-low AC
voltage protection |
P6 |
16 |
Outdoor unit over-high/over-low DC
voltage protection |
P7 |
17 |
IPM temperature overheat protection |
P8 |
18 |
Compressor discharge temperature overheat
protection |
P9 |
19 |
Cooling indoor unit coil anti-freezing
protection |
PU |
20 |
Cooling outdoor coil overheat protection |
PE |
21 |
Heating indoor coil overheat protection |
PC |
22 |
Cooling outdoor ambient temperature
over-low protection |
PH |
23 |
Heating outdoor ambient temperature
over-low protection |
L1 |
31 |
Drive bus voltage overload protection |
L2 |
32 |
Drive bus voltage over-low protection |
INDOOR FAULT |
||
E0 |
25 |
Indoor unit EEPROM fault |
E3 |
26 |
Indoor fan motor fault |
E2 |
27 |
Indoor PCB zero-crossing fault |
E5 |
28 |
Indoor evaporator temperature sensor
fault |
E4 |
29 |
Indoor room air temperature sensor fault |
EC |
30 |
Refrigerant Leakage Detection |